Research Article
Comparative Analysis of CTF and Trace Thermal-Hydraulic Codes Using OECD/NRC PSBT Benchmark Void Distribution Database
Table 8
Test conditions for transient void measurement test series 5T, 6T, and 7T.
| Test series | Assembly | Initial conditions | Transients | Pressure (kg/cm2a) | Mass flux (106 kg/m2h) | Power (kW) | Inlet temperature (Celsius) |
| 5T | B5 | 154.2 | 11.95 | 2282.0 | 300.4 | Power increase | 153.8 | 11.93 | 2244.0 | 301.2 | Flow reduction | 153.0 | 11.92 | 2236.0 | 300.4 | Depressurization | 152.5 | 11.94 | 2230.0 | 301.7 | Temperature increase |
| 6T | B6 | 158.2 | 11.55 | 2621.0 | 288.1 | Power increase | 158.4 | 12.03 | 2574.0 | 288.8 | Flow reduction | 154.6 | 12.02 | 2556.0 | 288.2 | Depressurization | 157.2 | 11.92 | 2603.0 | 288.8 | Temperature increase |
| 7T | B7 | 158.2 | 12.02 | 2500.0 | 291.9 | Power increase | 158.1 | 12.04 | 2405.0 | 292.0 | Flow reduction | 155.0 | 11.99 | 2577.0 | 291.8 | Depressurization | 158.8 | 11.99 | 2496.0 | 290.2 | Temperature increase |
|
|