Research Article

Long-Term Station Blackout Accident Analyses of a PWR with RELAP5/MOD3.3

Table 2

Times available before core uncovery and significant heatup as a function of depressurization.

ScenarioTime available before
Depressurization 1.33 MPaDepressurization 1.57 MPaDepressurization 2.06 MPaDepressurization 2.55 MPa
Core uncoverySignificant core heatupCore uncoverySignificant core heatupCore uncoverySignificant core heatupCore uncoverySignificant core heatup

S0-21>7 days>7 days>7 days>7 days>7 days>7 days>7 days>7 days
S0-50>7 days>7 days6 days 2 h6 days 23 h5 days 7 h5 days 22 h4 days 7 h4 days 18 h
S0-754 days 8 h4 days 23 h3 days 17 h4 days 6 h3 days 2 h3 days 12 h2 days 14 h2 days 20 h
S0-1003 day 3 h3 days 11 h2 days 17 h3 days2 days 6 h2 days 12 h1 day 18 h2 days
S0-1502 days2 days 6 h1 day 18 h1 day 23 h1 day 10 h1 day 16 h1 day 3 h1 day 7 h
S0-30022.4 h25.3 h19.8 h22.3 h15.4 h17.9 h12.4 h14.5 h
S0-300p>7 days>7 days>7 days>7 days>7 days>7 days>7 days>7 days
S1-2113.6 h14.2 h13.2 h13.8 h12.5 h13.1 h11.9 h12.6 h
S1-21v17.6 h8.3 h7.5 h8.2 h7.5 h8.1 h7.4 h8.0 h
S1-21v27.3 h8.2 h7.3 h7.9 h7.3 h7.8 h7.6 h8.3 h
S1-21p17.1 h18.7 h16.7 h18.2 h15.6 h17.4 h14.7 h16.9 h