Research Article

Effect of Flow Blockage on the Coolability during Reflood in a 2 2 Rod Bundle

Table 1

Main test conditions of the non-blockage tests.

(cm/s)/Test conditions (cm/s) (kPa) (°C) (kW/m)

1.01.03101.561.01.00
1.03101.547.81.50

1.51.55101.450.31.00
1.53101.449.21.49

2.02.06101.448.40.99
2.03101.446.11.50

2.52.55101.447.51.01
2.49101.547.41.51

3.53.43101.446.70.97
3.47101.549.81.50