Research Article

Thermomechanical Model and Bursting Tests to Evaluate the Risk of Swelling and Bursting of Modified 9Cr-1Mo Steel Steam Generator Tubes during a Sodium-Water Reaction Accident

Table 4

Comparison of rupture time of the 9% Cr with the experimental measures SQUAT.

SQUAT testTarget pressure (bar)Target temperature (°C)Bursting time measured (s)Bursting time calculated (s) MECTUB v2.0Relative error (%)

170128010.213.826.1
2170850>2150>25000
3170900460458−0.4
417095011197−14.4
517010003938−2,6
61701050 19.5200
7701100187141−32.6
87012004229−44.8
9701050390337−15.7
10701050401349−14.9