| Number | Name | Description | Nom. value | FV | RDF | RIF |
| 1 | LOOP | Loss of off-site power IE | 7,70E − 02 | 2,45E − 01 | 1,32E + 00 | Infinite | 2 | S1 | Medium LOCA IE | 1,00E − 03 | 2,07E − 01 | 1,26E + 00 | Infinite | 3 | AFW-XHE-FO-U1SBO | Operator failure to start AFW | 8,20E − 02 | 1,40E − 01 | 1,15E + 00 | 2,48E + 00 | 4 | AFW-TDP-FR-2P6HR | AFW failure to run | 3,00E − 02 | 1,31E − 01 | 1,15E + 00 | 5,23E + 00 | 5 | R | Manual reactor scram | 1,70E − 01 | 1,29E − 01 | 1,15E + 00 | 1,63E + 00 | 6 | ATWS | Anticipated transient WS IE | 5,00E − 04 | 1,29E − 01 | 1,15E + 00 | Infinite | 7 | HPI-XHE-FO-FDBLD | Operator failure feed/bleed | 7,10E − 02 | 1,28E − 01 | 1,15E + 00 | 2,68E + 00 | 8 | V | Interfacing LOCA IE | 1,60E − 06 | 1,03E − 01 | 1,12E + 00 | Infinite | 9 | T2 | Loss of main FW IE | 9,40E − 01 | 9,44E − 02 | 1,10E + 00 | Infinite | 10 | RECOV-S1-2 | Operator recovery action | 9,29E − 01 | 8,40E − 02 | 1,09E + 00 | 1,01E + 00 |
|
|