Research Article

Simulation of a TRIGA Reactor Core Blockage Using RELAP5 Code

Figure 4

Core nodalization showing in details the positions of the valves used to perform the partial core blockage (a); central cross view of the core nodalization (b). The valve number 38, connected to the element number 100, is used to perform the total core blockage.
(a)