Research Article

SIMMER-III Analyses of Local Fuel-Coolant Interactions in a Simulated Molten Fuel Pool: Effect of Coolant Quantity

Table 2

Condition of experimental tests performed [16].

Test numberMelt temperature (K)Melt volume (cc)Water temperature/subcooling (K)Water volume (cc)

16802154331 (42)5
2671331 (42)10
3675330 (43)20
4669330 (43)40
5674331 (42)60
6675331 (42)80
7673331 (42)96