Time constant of response for the three zones.
| Depressurization amplitude, bar | Maximum depressurization rate, bar/s | System, ms | Hot gas pipe, ms | Surge channel, ms | Insulation chamber, ms |
| 3 | 1657 | 1.81 | 13 | 3800 | 4560 | 5 | 2762 | 1.81 | 14 | 4213 | 5417 | 7 | 3867 | 1.81 | 19 | 4826 | 6636 | 9 | 4972 | 1.81 | 25 | 6205 | 7756 |
|
|