Research Article

CFD Analysis of the Primary Cooling System for the Small Modular Natural Circulation Lead Cooled Fast Reactor SNRLFR-100

Table 5

Difference between SNRLFR-100 design values and calculation results.

ParameterDesign value (°C)Calculation value (°C)

Average temperature of PHX inlet479.1479.5
Average temperature of PHX outlet400.0399.5
Average temperature of hot pool479.1479.5
Average temperature of cold pool400.0399.5
Average temperature of core inlet400.0399.5
Average temperature of core outlet480.0481.5