Research Article

An Association Rule Mining-Based Method for Revealing the Impact of Operational Sequence on Nuclear Power Plants Operating

Table 2

Part of the association rules.

NumberRuleSupportConfidence

1{Close source range channel: 0⟶1} {source range channel (point 2) of moving average: 0⟶1}180.62
2{Control rods of III withdrawal: 0⟶1, close source range channel: 0⟶1} {source range channel (point 2) of moving average: 0⟶1}150.83
3{Control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, close source range channel: 0⟶1} {source range channel (point 2) of moving average: 0⟶1}70.875
4{Control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, close source range channel: 0⟶1} {source range channel (point 2) of moving average: 0⟶1}51
5{Control rods of III withdrawal: 0⟶1, close source range channel: 0⟶1} {source range channel (point 2) of moving average: 1⟶0}150.83
6{Control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, close source range channel: 0⟶1} {source range channel (point 2) of moving average: 1⟶0}80.8
7{Control rods of III withdrawal: 0⟶1, close source range channel: 0⟶1} {source range channel (point 1) of moving average: 0⟶1}50.625
8{Control rods of II withdrawal: 0⟶1, control rod of II lower limit: 1⟶0} {source range channel (point 2) of differential: 0⟶1}60.67
9{Control rods of I withdrawal: 0⟶1, control rods of I withdrawal: 0⟶1, control rods of II withdrawal: 0⟶1, control rod of II lower limit: 1⟶0} {source range channel (point 2) of differential: 0⟶1}41
10{Control rods of III withdrawal: 0⟶1, control rod of III lower limit: 1⟶0} {source range channel (point 2) of threshold: 0⟶1}50.625
11{Control rods of II withdrawal: 0⟶1, control rods of III withdrawal: 0⟶1, control rod of III lower limit: 1⟶0} {source range channel (point 2) of threshold: 0⟶1}40.67
12{Control rods of III withdrawal: 0⟶1, control rod of III lower limit: 1⟶0} {source range channel (point 1) of differential: 0⟶1}31