Research Article

Case Study on Incentive Mechanism of Energy Efficiency Retrofit in Coal-Fueled Power Plant in China

Table 2

The key parameters of the project.

ItemValueUnitData source

Electricity supplied to the grid in year y ( )2,632,000MWhFeasibility study report of the project (FSR)
Standard coal consumption after retrofit322.5956kg/MWhEfficiency test report
Net calorific value of standard coal29,306MJ/tonEfficiency test report
Net calorific value of fossil coal23,026MJ/tonCalculated
Annual consumption of fossil coal1,080,643.24tonCalculated
Average net heat consumption of turbine after retrofit8738.92kJ/kWhEfficiency test report