Calculation worksheet for emission factor based on greenhouse gas measurement.
(a) Step 1 (fuel data) |
| Item | Carbon of fuel (as received basis) | Carbon of fuel (air-dried basis) | Carbon of fuel (dry basis) | Inherent moisture | Total moisture | Hydrogen |
| Subitem | | | ① | ② | ③ | ④ | Unit | (%) | (%) | (%) | (%) | (%) | (%) | Calculation | ①× ((100 − ② ) ÷ 100) | ①× ((100 − ③ ) ÷ 100) | | | | |
|
|
(b) Step 2 (raw data) |
| Item | Gross heating value | Net heating value | Fuel consumption rate | Heating output |
| Subitem | | | | | Unit | (kcal/kg) | TJ/ton | ton/h | TJ/h | Calculation | | ([A − {600 × (9 × ③ + ④ )}] × 4.18) × 10−6 | | |
|
|
(c) Step 3 (non-CO2 concentration) |
| Item | Volume concentration | Mass concentration | Flow rate |
| Subitem | | | | Unit | ppm | mg/m³ | m³/h | Calculation | | × (16 or ) | |
|
|
(d) Step 4 (non-CO2 emission) and Step 5 (non-CO2 emission factor) |
| Item | Non-CO2 emission | Non-CO2 emission factor |
| Subitem | | | Unit | g/h | kg/TJ | Calculation | | |
|
|