Research Article

Solid Phase Extraction of Inorganic Mercury Using 5-Phenylazo-8-hydroxyquinoline and Determination by Cold Vapor Atomic Fluorescence Spectroscopy in Natural Water Samples

Table 11

Simultaneous determination of metals in natural water samples by ICP-MS at pH 4.

Water samplesElementConcentration µg L−1Recovery (%)
Added Founda

Tap water
V00,320 ± 0,106
22,315 ± 0,2199,8
Co00,059 ± 0,004
22,041 ± 0,0299,1
Ni04,392 ± 0,037
26,172 ± 0,0596,5
Cu00,762 ± 0,137
22,759 ± 0,3299,9

River water
V00,606 ± 0,428
22,602 ± 0,5299,8
Co00,041 ± 0,014
22,030 ± 0,0599,4
Ni02,964 ± 0,377
24,790 ± 0,5296,4
Cu00,066 ± 0,42
22,065 ± 0,3299,9

The value following “ ” is the standard deviation .