Research Article

Integrated Electrokinetics-Adsorption Remediation of Saline-Sodic Soils: Effects of Voltage Gradient and Contaminant Concentration on Soil Electrical Conductivity

Table 2

Weekly results of electrical conductivity based on Box-Behnken Design.

Run orderPolarity reversal, A Voltage gradient, B Concentration, C Electrical conductivity dS/m
1st week2nd week3rd week

1240.66042.274.5150.1
200.26048.72176.7117.3
300.620102.682.93105.5
4480.62064.4191.3147.7
5240.66037.9867.05135.09
6480.26012.8537.894.75
7240.66046.4281.95165.11
84816084.990.12221.9
924120138.8103.2129.1
10240.2207.1416.8851.98
11240.210039.1136.3937.3
12016083.7876.8193.9
1300.610040.848.8225.64
14480.610055.2362.77124.1
1524110059.7486.9891.93