Research Article
Geometric Nonlinear Analysis of Self-Anchored Cable-Stayed Suspension Bridges
Table 1
Nonlinear effect of live load.
| | | Nonlinearity | Second-order | Relatively deviation% | Linear | Relatively deviation% |
| Moment at midspan of girder/(103 KN·m) | Max | 101.24 | 101.19 | −0.05 | 101.7 | 0.45 | Min | −15.00 | −14.96 | −0.27 | −15.04 | 0.27 | Moment at root of pylon/(103 KN·m) | Max | 285.61 | 283.20 | −0.84 | 162.80 | −47.79 | Min | −184.12 | −185.48 | 0.74 | −96.65 | −47.51 | Displacement at midspan of girder/(mm) | Max | 13.3 | 13.4 | 0.75 | 21.2 | 59.40 | Min | −1180 | −1186 | 0.51 | −1189 | 0.76 | Displacement at end of girder/(mm) | Max | 23.4 | 22.0 | −5.98 | 21.5 | −8.12 | Min | −0.84 | −0.86 | 2.38 | −0.36 | −57.14 | Displacement at top of pylon/(mm) | Max | 118.0 | 115.0 | −2.54 | 120.0 | 1.69 | Min | −6.6 | −6.6 | 0.00 | −9.1 | 37.88 |
|
|