| Model parameter | Value | Symbols/comments |
| PV system | 200 kWp | | BES system | 48 kWh | | BES terminal voltage | 240 V | | BES total capacity | 200 Ah | | System loads | 100 kW | | PCC system voltage | 11 kV | | G-VSC AC side voltage | 0.23 kV | | DC bus voltage | 500 V | | Capacitor | 10,000 uF, 50,000 uF | , | Inductor | 10 mH, 0.12 mH, 0.4 mH | | Transformer (TR1) | 0.1 MVA, 0.1 p.u. | Rating and leakage inductance | PI1, PI2 controller gains (G-VSC voltage mode) | 1, 0.005, 0.2, 1 | | PI3, PI4, PI5, PI6 controller gains (G-VSC current mode) | 2, 0.001, 0.6, 0.05, 0.1, 20, 5, 0.05 | | PI7, PI8 controller gains (BES DC/DC converter) | 1.2, 0.2, 1, 0.5 | | SOC limits | Max 0.95 p.u. Min 0.5 p.u. | | limits | Max 0.525 Min 0.475 | | Switching frequency | 2500 Hz | DC/DC (MPPT/buck-boost) and G-VSC | Simulation time step and running duration | 0.05 ms, 4 s | |
|
|