Research Article

The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation

Table 3

Maximum top displacements of 2nd transmission tower.

Seismic wave Peak acceleration (m/s2)Displacement (m)
X directionY direction
Without considering strain rateConsidering strain rateWithout considering strain rateConsidering strain rate

El Centro6.00.2430.2430.3300.329
8.00.2560.2580.4530.454
10.00.3390.3180.5140.513
12.00.4600.3960.6180.617
14.00.8410.7570.6910.687
15.0Collapse1.124Collapse0.706
16.0CollapseCollapseCollapseCollapse

Kobe6.00.4980.5010.5050.505
8.00.6850.6820.7010.694
10.01.0120.9730.9490.936
12.01.0851.0201.1211.084
13.01.1771.1091.2411.157
14.0Collapse1.196Collapse1.268
15.0CollapseCollapseCollapseCollapse

Northbridge10.00.3060.3050.3290.329
15.00.5180.5160.4530.455
20.00.5730.5680.4990.492
23.00.6810.6740.6440.640
25.00.7480.7250.6640.659
27.00.8280.8130.7430.740
29.0Collapse0.880Collapse0.752
30.0CollapseCollapseCollapseCollapse