Research Article
Multifunctional Voltage Source Inverter for Renewable Energy Integration and Power Quality Conditioning
Table 5
Simulation results with harmonics compensation.
| | RMS | Active power | Power factor | Current THD |
| Nonlinear load current | 13.5 A | 2162 W | 0.74 | 15.3% | Grid side (inductive-coupling VSI) | 7.76 A | 1707 W | 1.00 | 2.75% | Grid side (capacitive-coupling VSI) | 7.73 A | 1695 W | 1.00 | 2.00% |
|
|