Research Article

High Bulk Modulus of Ionic Liquid and Effects on Performance of Hydraulic System

Table 6

Absolute and relative errors of variables that were constant throughout a single measurement.

VariableSourceAbsolute/relative error

2,1 · 106 barSubjective estimation ±0,105 · 106 bar
5 mm 0,75% ±0,0375 mm 0,75%
20 mmBenteler tube data ±0,15 mm
1,5 mmNeglected
4,146 mMeasuring tape accuracy ±2 mm
4,475 m ±2 mm
4,50 m ±2 mm

Light face cells are calculated out of bold face cells (errors from source).