Research Article
Heat Removal from Bipolar Transistor by Loop Heat Pipe with Nickel and Copper Porous Structures
Table 5
Main design parameters of the LHP.
| Evaporator | | Total length (mm) | 130 | Active length (mm) | 86 | Outer/inner diameter (mm) | 28/26 | Material | Copper | Saddle | | Size (length/height/width) | 118/89/40 | Material | Alumina | Sintered copper powder | | Number of vapor grooves | 6 | Porosity (%) | 52–55 | Outer/inner diameter (mm) | 26/8 | Sintered nickel powder | | Number of vapor grooves | 6 | Porosity (%) | 67–70 | Outer/inner diameter (mm) | 26/8 | Compensation chamber | | Outer/inner diameter (mm) | 35/33 | Length (mm) | 110 | Charge mass | | Distilled water | 60% | Vapor line | | Length (mm) | 670 | Outer/inner diameter (mm) | 6/4 | Liquid line | | Length (mm) | 820 | Outer/inner diameter (mm) | 6/4 | Condenser | | Length (mm) | 420 | Outer/inner diameter (mm) | 6/4 |
|
|