Research Article

A Laboratory Based Investigation of a New Elastic Toothbrush Head

Table 2

% PI for type of toothbrush for the 14 casts % PI data.

Type of brushingManualElectric

Type of toothbrushStandardPrototypeStandardPrototype
Mean (standard deviation)Mean (standard deviation)Mean (standard deviation)Mean (standard deviation)

1st observation37.21 (20.56)25.29 (14.93)34.14 (18.38)19.93 (11.59)
2nd observation 37.50 (18.64)28.00 (15.88)33.79 (17.29)20.50 (10.78)
Total37.36 (19.26)26.6 (15.19)33.96 (17.51)20.21 (10.98)

GLM for repeated measuresMeasures   = 3.96   = 0.06
Toothbrush   = 2.61   = 0.12

Mean difference of PI between devices11%14%
95% CI of the difference−3%–24%2%–25%