Comparison of Internal Fixations for Distal Clavicular Fractures Based on Loading Tests and Finite Element Analyses
Table 1
Material properties of clavicle, acromion, plates, and fixture.
Mass density
Elastic
Poisson
(ton/mm
3
)
coefficient (MPa)
ratio (—)
Clavicle and acromion
10,000
0.3
Plates (titanium)
100,000
0.3
Fixture (rigid body)
—
—