Research Article
Stability Analysis of a Run-of-River Diversion Hydropower Plant with Surge Tank and Spillway in the Head Pond
Table 1
Plant dimensions, parameters and base values.
| Element | Parameter | Value |
| Base values | Base head | | 165.19 m | Base flow | | 20 m3/s |
| Head pond | Horizontal section | | 900 m2 | Spillway length | | 9.00 m | Spillway level | | 450.90 masl | Water level reference under normal conditions | | 450.10 masl | Water level reference under flood conditions | | 451.40 masl | | 0.012 |
| Head race conduit | Length | | 5201 m | Section | | 5.31 m2 | Losses | | 13.21 m | Losses (p.u.) | | 0.080 p.u. | Time constant | | 12.09 s | Initial head-race conduit flow | | 1.00 p.u. |
| Surge tank | Section | | 9.62 m2 | Thoma section | | 9.15 m2 | | 1.052 | | 93.54 |
| Penstock | Length | | 801.15 m | Section | | 5.31 m2 | Losses | | 3.45 m |
| Turbine | | 0.596 | | 0.978 |
|
|