Research Article
Optimization of Electrochemical Treatment Process Conditions for Distillery Effluent Using Response Surface Methodology
Table 3
Experimental design, observed yields in BBD experiments in terms of percentage removal of COD and color.
| Run | pH | Electrolysis time (min) | Current density (mA/cm2) | Electrolyte concentration (g/L) | COD removal (%) | Color removal (%) |
| 1 | 5 | 90 | 20 | 1.5 | 84.54 | 89.22 | 2 | 3 | 90 | 35 | 1.5 | 85.56 | 92.18 | 3 | 5 | 120 | 35 | 1.5 | 83.86 | 83.32 | 4 | 5 | 90 | 35 | 1.0 | 76.52 | 86.27 | 5 | 1 | 90 | 20 | 1.5 | 76.22 | 60.47 | 6 | 5 | 90 | 35 | 2.0 | 87.22 | 92.33 | 7 | 3 | 60 | 20 | 1.5 | 68.99 | 45.26 | 8 | 3 | 60 | 35 | 1.0 | 32.15 | 37.24 | 9 | 3 | 90 | 35 | 1.5 | 86.43 | 91.18 | 10 | 1 | 90 | 35 | 1.0 | 48.52 | 52.33 | 11 | 3 | 90 | 50 | 1.0 | 57.12 | 82.31 | 12 | 3 | 60 | 50 | 1.5 | 45.96 | 50.25 | 13 | 3 | 60 | 20 | 2.0 | 74.49 | 76.37 | 14 | 3 | 90 | 50 | 2.0 | 84.45 | 94.42 | 15 | 3 | 120 | 50 | 1.5 | 74.37 | 80.43 | 16 | 1 | 60 | 35 | 1.5 | 59.91 | 35.19 | 17 | 3 | 90 | 35 | 1.5 | 86.43 | 91.16 | 18 | 3 | 120 | 35 | 2.0 | 69.38 | 76.42 | 19 | 3 | 90 | 35 | 1.5 | 86.48 | 91.23 | 20 | 3 | 90 | 35 | 1.5 | 86.75 | 91.16 | 21 | 1 | 120 | 35 | 1.5 | 61.18 | 67.09 | 22 | 3 | 60 | 35 | 2.0 | 61.96 | 82.89 | 23 | 3 | 120 | 20 | 1.5 | 74.43 | 80.36 | 24 | 3 | 90 | 20 | 1.0 | 65.76 | 71.32 | 25 | 1 | 90 | 35 | 2.0 | 71.36 | 76.44 | 26 | 5 | 90 | 50 | 1.5 | 73.24 | 80.21 | 27 | 5 | 60 | 35 | 1.5 | 55.12 | 62.42 | 28 | 3 | 120 | 35 | 1.0 | 69.49 | 76.91 | 29 | 1 | 90 | 50 | 1.5 | 59.45 | 70.54 |
|
|