Research Article

Optimal Pipe Size Design for Looped Irrigation Water Supply System Using Harmony Search: Saemangeum Project Area

Table 6

Analysis results of the optimal and initial hydraulic designs (based on statistical values of the nodal head and pipe velocity).

Target water supply networkNodal pressure head (m)Pipe velocity (m/s)
Min.Max.Avg.Var.Min.Max.Avg.Var.

Six zones of Saemangeum (looped type)17.6531.6623.0413.950.011.920.970.16
Optimal design10.0029.0815.3623.680.022.461.180.29