Research Article
Ensemble Classifier for Epileptic Seizure Detection for Imperfect EEG Data
Table 6
Performance of the classifiers with CR = 85.35% for SNR = 1, 5, and 10 dB and noiseless EEG data.
| | SNR | PR | RE | AC | | | | | | | | AVG | STD |
| ANN | 1 | 0.66 | 0.73 | 0.99 | 0.80 | 0.61 | 0.94 | 0.78 | 0.17 | 5 | 0.74 | 0.88 | 0.99 | 0.84 | 0.68 | 0.95 | 0.82 | 0.14 | 10 | 0.80 | 0.85 | 0.98 | 0.88 | 0.75 | 0.96 | 0.86 | 0.11 | Noiseless | 0.86 | 0.82 | 0.92 | 0.84 | 0.82 | 0.96 | 0.87 | 0.08 |
| NB | 1 | 0.67 | 0.75 | 0.99 | 0.80 | 0.59 | 0.96 | 0.78 | 0.19 | 5 | 0.71 | 0.79 | 0.98 | 0.88 | 0.62 | 0.96 | 0.82 | 0.18 | 10 | 0.76 | 0.83 | 0.97 | 0.90 | 0.69 | 0.96 | 0.85 | 0.14 | Noiseless | 0.80 | 0.87 | 0.98 | 0.90 | 0.75 | 0.99 | 0.86 | 0.12 |
| -NN | 1 | 0.64 | 0.73 | 0.99 | 0.92 | 0.53 | 0.93 | 0.77 | 0.23 | 5 | 0.65 | 0.71 | 1.00 | 0.91 | 0.50 | 0.89 | 0.78 | 0.21 | 10 | 0.71 | 0.80 | 1.00 | 0.98 | 0.59 | 0.87 | 0.81 | 0.20 | Noiseless | 0.72 | 0.83 | 1.00 | 0.96 | 0.63 | 0.90 | 0.83 | 0.18 |
| SVM | 1 | 0.70 | 0.69 | 1.00 | 0.81 | 0.70 | 0.82 | 0.78 | 0.07 | 5 | 0.73 | 0.78 | 1.00 | 0.87 | 0.78 | 0.82 | 0.82 | 0.05 | 10 | 0.76 | 0.84 | 1.00 | 0.94 | 0.80 | 0.82 | 0.85 | 0.08 | Noiseless | 0.79 | 0.84 | 1.00 | 0.97 | 0.81 | 0.81 | 0.86 | 0.09 |
| NSC | 1 | 0.65 | 0.86 | 0.98 | 0.92 | 0.48 | 1.00 | 0.80 | 0.28 | 5 | 0.70 | 0.93 | 0.98 | 0.96 | 0.56 | 1.00 | 0.84 | 0.24 | 10 | 0.77 | 1.00 | 0.94 | 1.00 | 0.64 | 1.00 | 0.88 | 0.21 | Noiseless | 0.83 | 0.95 | 0.94 | 0.98 | 0.74 | 0.98 | 0.90 | 0.14 |
|
|