Research Article

ADC Production Test Technique Using Low-Resolution Arbitrary Waveform Generator

Table 7

THD estimation accuracy versus AWG resolution.

AWG resolution THD reference (dB) THD estimation (dB) Measurement difference (dB)

ADC#112−61.8−61.7−0.1
10−61.8−62.00.2
8−61.8−62.40.6
6−61.8−61.7−0.1

ADC#212−59.8−59.1−0.7
10−59.8−58.8−1.0
8−59.8−58.9−0.9
6−59.8−59.1−0.8