Research Article

Lossless and Low-Power Image Compressor for Wireless Capsule Endoscopy

Table 2

Comparison of performance with other schemes.

Prediction modeAverage CR%Overall PSNR (dB)
Encoding (without clipping)Encoding + Clipping

Proposed167.073.2 (lossless)
266.372.6
360.067.8
472.076.8
570.576.0
670.175.7
768.374.6

Chen et al. [14] 56.746.4
Xiang et al. [15]72.746.8
Wahid et al. [9]87.132.9
Turcza and Duplaga [10]32.036.5
Lin et al. [11]79.632.5
JPEG-FP [9, 25]81.531.5
Hu et al. [26]72.0 ( 𝑄 level = 2)39.6
Wu and Li [27]50.031.0
Dung et al. [28]82.036.2