Abstract

The corrosion inhibition efficiency of a potential polynuclear Schiff base, (s)-2-(anthracene-9 (10H)-ylidene amino)-5-guanidinopentanoic acid (A9Y5GPA), on carbon steel (CS) in 1 M hydrochloric acid solution has been investigated using weight loss measurements, electrochemical impedance spectroscopy (EIS), and potentiodynamic polarization studies. The corrosion inhibition efficiencies of parent amine [(s)-2-amino-5-guanidinopentanoic acid] and parent ketone (anthracene-9 (10H)-one) on carbon steel in 1.0 M hydrochloric acid solution have also been investigated using weight loss studies. The electrochemical and weight loss data established that the inhibition efficiency on CS increases with the increase in the concentration of inhibitor, A9Y5GPA. The adsorption of A9Y5GPA obeys the Langmuir adsorption isotherm. Thermodynamic parameters (, ) were calculated using the adsorption isotherm. Activation parameters of the corrosion process (, and ) were also calculated from the corrosion rates obtained from temperature studies. Tafel plot analysis revealed that A9Y5GPA acts as a mixed-type inhibitor. A probable inhibition mechanism was also proposed. Surface morphology of the carbon steel specimens in the presence and absence of the inhibitor was evaluated by SEM analysis.

1. Introduction

The use of hydrochloric acid in metal industries for acid pickling, descaling, and cleaning process is the major reason for the increase in the dissolution rate of carbon steel. The use of certain organic compounds as inhibitors is the most practical method to prevent corrosion of the carbon steel (CS) in acidic media [13]. Compounds with -bonds generally exhibit good inhibitive properties due to interaction of -orbital with the metal surface [4]. Schiff bases are organic molecules possessing azomethine linkage and many of them act as effective potential corrosion inhibitors [58]. Increasing efforts have been made to study the corrosion behavior of metals and mechanism of inhibition during the past decade mainly through electrochemical investigations [911]. The present investigation was undertaken to examine the corrosion inhibition behavior of a novel polynuclear Schiff base (A9Y5GPA) derived from anthracene-9 (10H)-one and (s)-2-amino-5-guanidinopentanoic acid in 1 M HCl solution on CS at different temperatures. The study was performed by weight loss measurements, electrochemical impedance spectroscopy (EIS), and potentiodynamic polarization analysis.

2. Experimental

2.1. Inhibitor

Polynuclear Schiff base (A9Y5GPA) was obtained by the condensation of equimolar mixture of anthracene-9 (10H)-one and (s)-2-amino-5-guanidinopentanoic acid in ethanol. The reaction mixture was refluxed for 5 hours, cooled by keeping overnight to obtain dark-coloured compound, filtered, washed, and dried. Figure 1 shows the molecular structure of polynuclear Schiff base A9Y5GPA. Anal.calcd for C20H22N4O2: C, 68.49; H, 6.28; N, 15.98%. Found. C, 67.86; H, 7.24; N, 15.64%; ; IR (KBr):  cm−1,  cm−1,  cm−1 (doublet), 3,304 cm−1. 1Hnmr: 12.21, , . 13Cnmr: , ,  ppm.

2.2. Solutions

The aggressive solution of 1 M HCl was prepared by dilution of A.R grade 37% of HCl (Merck) with de-ionized water. Inhibitor solutions were prepared in the range, 0.2 mM–1.0 mM concentrations.

2.3. Weight Loss Measurements

Mild steel specimens of dimension  cm were cut and abraded with various grades of silicon carbide papers (200, 400, 600, 800, 1000, 1200, and 2000). The chemical composition of CS specimens was determined by EDX analysis and found to be (approx.) C, 0.5%; Mn, 0.07%; P, 0.02%; S, 0.015%; Si, 0.02% and rest Fe. The exact area and thickness of each coupon were measured and washed with soap water. Specimens were then degreased again with acetone and finally dried. After weighing, specimens were immersed in 50 mL acid solutions (naturally aerated) at 30–60°C in the absence and presence of the inhibitor (A9Y5GPA) using hooks and fishing lines. Weight loss of metal specimens was noted after 24 h. The experiments were carried out in duplicate and the average values were reported. The corrosion rate () and the percentage of inhibition efficiency () were calculated by the following equations [12, 13]: where is the weight loss (g) of specimen, is the total area (cm2) of specimens, is the time of treatment (24 h), and and are the corrosion rates (mmy−1) of uninhibited and inhibited specimens, respectively.

2.4. Electrochemical Impedance Spectroscopy (EIS)

The EIS measurements were performed in a three-electrode cell assembly. Saturated calomel electrode (SCE) was used as the reference electrode. Platinum electrode having 1 cm2 area was taken as counter electrode. Metal specimens with an exposed area of 1 cm2 were used as the working electrode. The EIS experiments were carried out on an Ivium compactstat-e electrochemical system. 1 M HCl (no stirring) was taken as the electrolyte and the working area of the metal specimens was exposed to the electrolyte for 1 h prior to the measurement. EIS measurements were performed at constant potential (OCP) in the frequency range from 1 KHz to 100 mHz with amplitude of 10 mV as excitation signal. The percentage of inhibitions from impedance measurements was calculated using charge transfer resistance values by the following expression [14]: where and are the charge transfer resistance of working electrode with and without inhibitor, respectively.

2.5. Potentiodynamic Polarization Studies

Electrochemical polarization studies on CS specimens in 1 M HCl with and without inhibitor were performed by recording anodic and cathodic potentiodynamic polarization curves. Polarization plots were obtained in the electrode potential range from −100 to +100 mV versus equilibrium potential () at a scan rate of 1 mV/sec. Tafel polarization analysis was done by extrapolating anodic and cathodic curves to obtain corrosion current densities (). The percentage of inhibition efficiency (%) was evaluated from the measured values using the following relation [15]: where and are the corrosion current densities of the exposed area of the working electrode in the absence and presence of inhibitor, respectively.

From the slope analysis of the linear polarization curves in the vicinity of corrosion potential of blank and different concentrations of the inhibitor, the values of polarization resistance () in 1 M HCl solution were obtained. From the evaluated polarization resistance, the inhibition efficiency was calculated using the relationship where and are the polarization resistance in the presence and absence of inhibitor, respectively [16].

2.6. Scanning Electron Microscopy

Surface analyses were performed using scanning electron microscope (model: Hitachi SU6600). SEM images were obtained from CS surface after the immersion in 1 M HCl solutions in the absence and presence of the inhibitor A9Y5GPA (1 mM) for 24 h at 30°C.

3. Results and Discussion

3.1. Weight Loss Measurements

Weight loss of CS specimens in 1 M HCl at 30°C was determined at 24 h in the presence of various concentrations of inhibitor (A9Y5GPA). The corrosion rates, inhibition efficiencies, and surface coverage () in the presence of inhibitor for CS specimens for the period of 24 h are shown in the Table 1. Data clearly established that the corrosion rate markedly decreased with inhibitor concentration from 0 to 0.2 mM. Beyond this concentration, corrosion rate showed a gradual decrease. This response is due to the fact that the surface coverage () of the inhibitor molecules on the metal through adsorption increases with the increase in concentration. At the inhibitor concentration of 1.0 mM, the maximum was 73.50, which shows that A9Y5GPA acts as good corrosion inhibitor for CS in HCl.

3.2. Comparison of Inhibition Efficiency of Schiff Base with Its Parent Compounds

To compare the inhibition efficiencies of Schiff base, parent ketone (anthracene-9 (10H)-one), and parent amine [(s)-2-amino-5-guanidinopentanoic acid], weight loss measurements of CS specimens were performed in 1 M HCl at 30°C. The percentage of corrosion inhibition efficiencies obtained for Schiff base, parent ketone, and parent amine on CS is represented in Figure 2. The inhibition efficiency of the Schiff base A9Y5GPA was markedly higher than that of parent ketone and parent amine for the studied concentrations. This investigation clearly establishes the role of azomethine linkage (C=N) present in the Schiff base which actively participates in the corrosion inhibition mechanism.

3.3. Adsorption Isotherm and Free Energy of Adsorption

The mechanism of adsorption and the surface behavior of organic molecules can be easily viewed through adsorption isotherms. Different models of adsorption isotherms considered are Langmuir, Temkin, Frumkin, and Freundlich isotherms. For the evaluation of thermodynamic parameters, it is necessary to determine the best fit isotherm with the aid of correlation coefficient (). Among the isotherms mentioned above, the best description of the adsorption behavior of A9Y5GPA on CS specimens in 1 M HCl was Langmuir adsorption isotherm and the model is expressed as follows [17]: where is the concentration of the inhibitor, is the fractional surface coverage, and is the adsorption equilibrium constant. Figure 3 represents the adsorption plot of A9Y5GPA obtained by the weight loss measurements of CS steel specimens in 1 M HCl at 30°C for 24 h.

The value of adsorption equilibrium constant is 4316 and is related to the standard free energy of adsorption : where 55.5 is the molar concentration of water, is the universal gas constant, and is the temperature in Kelvin [18]. for A9Y5GPA on CS showed negative values indicating the spontaneity of the process. The value of up to −20 kJ mol−1 is an indication of the electrostatic interaction of the charged molecule, and the charged surface of the metal (physisorption) while is more negative than −40 kJ implies that inhibitor molecules are adsorbed strongly on the metal surface through coordinate-type bond (chemisorption) [19, 20]. In the present investigation, the inhibitor molecules showed   −31.16 kJ/mol for CS specimens, suggesting that the adsorption of inhibitor involves both electrostatic and chemical interactions.

3.4. Effect of Temperature

The effect of temperature on corrosion was also evaluated using weight loss measurement in the temperature range of 30–60°C. The activation energy of corrosion with and without the inhibitor could be calculated by the Arrhenius equation: where is the rate of corrosion, is the activation energy, is the frequency factor, is the temperature in Kelvin scale, and is the gas constant. Linear plots between and (Figure 4) having regression coefficients close to unity indicate that the corrosion of CS in HCl could be explained by the simple kinetic model. Enthalpy and entropy of activation (, ) were calculated from the transition state theory [21]: where is the Avogadro number and is the Planks constant. A plot of versus gave straight lines for the corrosion of CS in 1 M HCl in the presence and absence of the inhibitor (Figure 5). Table 2 shows the activation energy and thermodynamic parameters of corrosion of CS in 1 M HCl with and without the inhibitor A9Y5GPA. Activation energy of dissolution of the metal increased with the inhibitor concentration. This implies that the reluctance of dissolution of metal was increased with the inhibitor concentration. Positive signs of enthalpies with a regular rise reflect the endothermic nature of dissolution and the increasing difficulty of corrosion with the inhibitor. It is evident from Table 2 that the entropy of activation increases with the inhibitor concentration. For the blank and 0.2 mM concentration of the inhibitor, the entropy of activation is large and negative. This implies that, in the rate determining step, a decrease in disordering takes place on going from reactants to the activated complex, and the activated molecules were in higher order state than that at the initial state. But as the concentration of inhibitor rises, the disordering of activated complex rises and the entropy of activation acquires positive values.

3.5. EIS Measurements

The corrosion response of CS in 1 M HCl in the presence of various concentrations of inhibitor has been investigated using electrochemical impedance spectroscopy at 30°C. Figures 6(a) and 6(b) represent the Nyquist plots and the Bode plots, respectively for CS specimens in 1 M HCl in the presence of various concentrations of inhibitor. It is evident from the plots that the impedance response of metal specimens has marked difference in the presence and absence of the inhibitor A9Y5GPA.

Impedance behavior can be well explained by pure electric models that could verify and enable the calculation of numerical values corresponding to the physical and chemical properties of electrochemical system under examination [22]. The simple equivalent circuit that fits to many electrochemical systems is composed of a double-layer capacitance, and [23, 24]. To reduce the effects due to surface irregularities of metal, constant phase element (CPE) is introduced into the circuit instead of a pure double-layer capacitance which gives more accurate fit [25] as shown in Figure 7.

The impedance of CPE can be expressed as where is the magnitude of CPE, is the exponent (phase shift), is the angular frequency, and is the imaginary unit. CPE may be resistance, capacitance, and inductance depending upon the values of [26]. In all experiments, the observed value of ranges between 0.75 and 1.0, suggesting the capacitive response of CPE. The EIS parameters such as , CPE, and the calculated values of percentage of inhibition (%) of CS specimens are listed in Table 3.

From Table 3, it is clear that values are increased with increasing inhibitor concentration. The capacitance value decreases with inhibitor concentration, and this decrease in may be explained on the basis that the double layer between the charged metal surface and the solution would act as an electrical capacitor. These results suggest that the A9Y5GPA molecules function by adsorption at the metal/solution interface [27]. A maximum of 91.65% inhibition efficiency could be achieved at an inhibitor concentration of 1 mM for CS specimen.

3.6. Potentiodynamic Polarization Studies

Figures 8(a) and 8(b) represent potentiodynamic and linear polarization curves for CS specimens in 1 M HCl at 30°C for CS specimens in the presence of various concentrations of inhibitor (A9Y5GPA). Polarization parameters like corrosion current densities (), corrosion potential (), cathodic Tafel slope (), anodic Tafel slope (), and inhibition efficiency (%) and linear polarization parameters like polarization resistance () and inhibition efficiency (%) for CS specimens are listed in Table 4. A marked decrease in the corrosion current density () was observed in the presence of inhibitor A9Y5GPA. The lowest value of was noticed for the inhibitor solution of concentration 1 mM which exhibited a maximum inhibition efficiency of 89.08%. The data show that addition of the Schiff base to acid media affected both the cathodic and anodic parts of the curves; it may be assumed that the inhibitor molecules are adsorbed on anodic and cathodic sites uniformly. Generally, if the shift of is >85 with respect to of uninhibited solution, the inhibitor can be viewed as either cathodic or anodic type [28, 29]. In the present study, the maximum shift of is 21 mV, suggesting that A9Y5GPA acts as a mixed-type inhibitor for CS specimens in 1 M HCl.

3.7. SEM Studies

The surface morphology of carbon steel surface was evaluated by scanning electron microscopy (SEM). Figures 9(a), 9(b), and 9(c) show the scanning electron micrographs of the bare carbon steel surface, CS specimens with and without inhibitor in hydrochloric acid medium, respectively. The morphology revealed that, in the absence of A9Y5GPA, the surface is highly corroded. However in the presence of inhibitor the rate of corrosion is suppressed. These observations suggest that the inhibitor forms a protective layer on the surface that prevents the attack of acid on the corroding metal CS.

3.8. Mechanism of Inhibition

It is well known that the surface of the metal is positively charged in acidic media [30]. It is believed that the Cl ions could be specifically adsorbed on the metal surface and create an excess of negative charge on the surface. This will favour the adsorption of protonated Schiff base (A9Y5GPA+) on the surface [31] and hence reduce the dissolution of Fe to Fe2+ (Figure 10). Besides this electrostatic interaction between the protonated Schiff base and the metal surface, other possible interactions are (i) interaction of unshared electron pairs in the molecule with the metal, (ii) interaction of -electrons with the metal, and (iii) a combination of types (i)-(ii) [32, 33]. The -electron cloud of the aromatic rings and the azomethine linkage also participate in the inhibition mechanism. Furthermore, the double bonds in the inhibitor molecule permit the back donation of metal d electrons to the orbital, and this type of interaction cannot occur with amines [34]. This can be justified by the lower inhibition efficiency of the parent amine than that of the Schiff base.

4. Conclusions

(1)A9Y5GPA acts as good inhibitor for CS in 1 M hydrochloric acid medium.(2)Inhibition efficiency increases with the increase in concentration of inhibitor.(3)Compared to the parent amine and ketone, the Schiff base A9Y5GPA exhibited higher inhibition efficiency for CS.(4)The inhibition mechanism is explained by adsorption. The adsorption of A9Y5GPA obeys the Langmuir adsorption isotherm.(5)The thermodynamic parameters calculated from the adsorption isotherms showed that both physisorption and chemisorption are involved in the inhibition process.