Research Article

Additive Manufacturing of Silencers with Microperforates

Table 2

Measured impedances of the three MPP-gap options at 3500 Hz compared to optimal value.

ā€‰Measured VA One prediction using theory in [15]
OptionReal PartImaginary partReal PartImaginary part

A1.030.730.460.08

B0.870.0480.330.09

C0.430.180.100.028

ā€‰Optimum according to equation (2) for R=0.0174 m at 3500 Hz
Real PartImaginary part
0.31-0.13