Research Article

Sensitivity Analysis of the Influence of Structural Parameters on Dynamic Behaviour of Highly Redundant Cable-Stayed Bridges

Table 7

Comparison between calculated FE and measured frequencies.

ModesMeasured frequencies (Hz)FE calculated frequencies (Hz) Final frequency error (%)
Initial FE frequency (HZ)Estimated frequencies
FirstSecondThirdForth

TL10.0970.1200.1200.1100.1000.1003
TL20.2480.3200.2690.2600.2550.2503
TL30.4700.5640.3900.4100.4500.4631
V10.2250.2160.2200.2180.2180.2183
V20.2630.2700.2690.2690.2670.2671
V30.3650.3670.3670.3700.3700.3701