Research Article

Development and Performance Evaluation of Light Shelves Using Width-Adjustable Reflectors

Table 8

Performance evaluation results for a light shelf with a width-adjustable reflector.

SeasonLight shelfIllumination sensor (lx)Uniformity ratioLighting dimming control: lighting number (dimming level)Electricity consumption (kWh)
Optimum width (m)AngleMinimumAverage

Summer0.6−10°72.1230.70.3121 (8)→3 (8)→2 (2)0.124
76.1243.80.3121 (8)→3 (8)→2 (2)0.124
10°83.3259.80.3211 (8)→3 (8)→2 (2)0.124
20°89.1276.10.3231 (8)→3 (8)→2 (1)0.114
30°96.0281.90.3411 (8)→3 (8)→2 (1)0.114
Middle season0.2−10°88.8280.60.3161 (8)→3 (8)→2 (2)0.124
90.2286.30.3151 (8)→3 (8)→2 (2)0.124
10°92.9293.50.3161 (8)→3 (8)→2 (1)0.114
20°93.8296.00.3171 (8)→3 (8)→2 (1)0.114
30°98.0299.90.3271 (8)→3 (8)0.102
Winter0.1−10°177.2625.550.2831 (8)→3 (2)0.069
177.6640.240.2771 (8)→3 (2)0.069
10°182.4656.490.2781 (8)0.012
20°189.2677.520.2791 (8)0.012
30°194.3672.780.2891 (8)0.012
Total electricity consumption (kWh):0.228