Research Article

Physical Modeling of Displacement and Failure Monitoring of Underground Roadway in Horizontal Strata

Table 5

Layout and number of monitoring bolt devices.

Layout positionNumberTypeLength of the bolt (mm)Length of the constant resistance device (mm)Load value (N)Constant resistance value (N)

Bolt in roofR1Constant resistance bolt40040247.0222.3
R2Traditional bolt4000247.0No
R3Constant resistance bolt40040247.0222.3
R4Traditional bolt4000247.0No

Bolt on both sidesS1Constant resistance bolt2704079.071.1
S2Traditional bolt270079.0No
S3Constant resistance bolt2704079.071.1
S4Traditional bolt270079.0No