Research Article

A Combined Modal Correlation Criterion for Structural Damage Identification with Noisy Modal Data

Table 2

Beam example: norm values for different damage scenarios and 1 to 4 known modes (noise 5%).

Known modesDamage scenario
1234

1 mode0.1370.3700.4250.307
2 modes0.1370.0870.0930.313
3 modes0.0000.0000.0250.128
4 modes0.0000.0000.0000.098