Research Article

Uplift Test and Design Method for Bearing Capacity of Isolated Spread Concrete Foundation Slab with Large Width-to-Height Ratio

Table 9

Acting forces of the foundations.

NumberType of towerRotation degree of high-voltage line (°)Acting forces (ultimate value) (unit: kN)
TmaxTxTyNmaxNxNy

15D1-SJC3-3050–603847.1702.1658.14485.4815.1717.1
25D1-SJC4-3670–804161.4813.5788.04851.7959.6874.6
3SJ164-4550–604533.0848.3848.25168.31024.4924.5