Research Article

Probability-Based Sensitivity of Service Life of Chloride-Attacked Concrete Structures with Multiple Cover Concrete Repairs

Table 2

Six proposed repair strategies for corrosion-free condition.

Code of repairsRepair application timeDiffusion coefficient of repair material, DrepDepth of repairs, Xp

S1: DCWhenever ClTH,T = CCritDoCover
S2: DC35DoCover + 35 mm
S3: 75DC0.75DoCover
S4: 75DC350.75DoCover + 35 mm
S5: 75DC500.75DoCover + 50 mm
S6: 50DC500.5DoCover + 50 mm

ClTH,T means chloride content at the threshold depth TH and time T. CCrit means critical chloride.