Research Article
Optimal Analysis of Tunnel Construction Methods through Cross Passage from Subway Shaft
Table 1
Shaft support parameters.
| Item | Main materials and specifications | Structure size |
| Support | Leading conduit | Φ423.5, length = 2 m and 3.5 m, steel flower tube | Spacing: 1.01.0 m and 1.51.5 m | Grid steel frame | C25, C14 steel | Vertical clearance: 0.75 and 0. 5 m | Mesh reinforcement | Φ8 150150 m grid | Surrounded by laying, double | Vertical reinforcement | C22 steel bar | Ring spacing: 1.0 m, double | Shotcrete | C25 early strength concrete | Thickness: 0.4 m |
|
|