Research Article

Effects of Burial Depth on the Seismic Response of Subway Station Structure Embedded in Saturated Soft Soil

Table 2

The maximum axial forces at typical sections of the structure with different burial depths (unit: kN).

Burial depth (m)P11P12P13P14P6P8P10

2 m5505445265987682201783
5 m1331134213171382163637781648
8 m2028204520092095245454272484
11 m2686 (↑388%)2661 (↑389%)2606 (↑395%)2761 (↑362%)3239 (↑322%)7080 (↑222%)3281 (↑319%)

Burial depth (m)P1P2P3P4P5P7P9
2 m2335220021962332151222691499
5 m2880270927092869236238482320
8 m3348311631443314321654953114
11 m3844 (↑65%)3568 (↑62%)3583 (↑63%)3843 (↑65%)4174 (↑176%)7150 (↑215%)3889 (↑159%)