Research Article
Dynamic Modification and Damage Propagation of a Two-Storey Full-Scale Masonry Building
Table 1
Modal participation factors (MPFs) in x and y directions of the six test phases.
| ā | ā | MPF in x direction | MPF in y direction | 1 | 2 | 3 | 4 | 1 | 2 | 3 | 4 |
| Phase | 1 | 0.67 | 0.13 | 0.11 | 0.05 | 0.00 | 0.61 | 0.18 | 0.16 | 2 | 0.65 | 0.12 | 0.12 | 0.06 | 0.00 | 0.69 | 0.10 | 0.15 | 3 | 0.59 | 0.17 | 0.14 | 0.05 | 0.07 | 0.69 | 0.03 | 0.14 | 4 | 0.52 | 0.17 | 0.01 | 0.23 | 0.06 | 0.86 | 0.03 | 0.01 | 5 | 0.42 | 0.01 | 0.01 | 0.46 | 0.00 | 0.86 | 0.01 | 0.06 | 6 | 0.52 | 0.13 | 0.24 | 0.06 | 0.00 | 0.89 | 0.04 | 0.01 |
|
|