Research Article

Dynamic Modification and Damage Propagation of a Two-Storey Full-Scale Masonry Building

Table 1

Modal participation factors (MPFs) in x and y directions of the six test phases.

ā€‰ā€‰MPF in x directionMPF in y direction
12341234

Phase10.670.130.110.050.000.610.180.16
20.650.120.120.060.000.690.100.15
30.590.170.140.050.070.690.030.14
40.520.170.010.230.060.860.030.01
50.420.010.010.460.000.860.010.06
60.520.130.240.060.000.890.040.01