Research Article

Investigation of the Effect of Larestan’s Pipeline Water on the Mechanical Properties of Concretes Containing Granite Aggregates

Table 6

The results of the compressive strength test of normal concrete samples made by using tap water and pipeline water.

Age (day)Tap water concrete (MPa)Pipeline water concrete (MPa)Strength decline (%)

717.414.814.9425
1423.920.912.5523
2829.426.210.8843
5630.327.49.57095
9036.433.28.79120