Research Article

Quantifying Repeatability Reproducibility Sources of Error and Capacity of a Measurement: Demonstrated Using Laboratory Soil Plasticity Tests

Table 3

Summary of the standard deviation of the liquid limit test results determined using the two tests.

Bentonite content (%)Standard deviation (%)
Casagrande cupFall cone

00.240.21
30.280.38
60.570.4
91.670.67
122.930.92