Research Article
Test and Numerical Study on Monotonic Behavior of Complex CFT Column Joints
Table 5
Stress comparison of the A1 joint.
| Monitoring point | Test results (MPa) | Finite element results (MPa) | Deviation (%) |
| 3 | 490.06 | 439.44 | 10.33 | 9 | 339.49 | 296.24 | 12.74 | 13 | 68.78 | 60.75 | 11.67 | 19 | 132.60 | 135.59 | 2.25 | 25 | 209.86 | 230.79 | 9.97 | 31 | 151.18 | 138.82 | 8.18 | 35 | 227.82 | 194.16 | 14.77 | 58 | 133.33 | 121.56 | 8.83 |
|
|