Research Article
Stochastic Inversion Method for Concrete Dams on the Basis of Bayesian Back Analysis Theory
Table 2
Initial modulus and ranges of different zones.
| Zone | Initial modulus (GPa) | Range of modulus mean value (GPa) | Range of modulus variable coefficient | Range of correlation distance (m) | Min | Max | Min | Max | Min | Max |
| Zone A | 27.2 | 10.0 | 40.0 | 0.02 | 0.3 | 0.2 | 10 | Zone B | 24.1 | 10.0 | 40.0 | 0.02 | 0.3 | 0.2 | 10 | Zone C | 35.4 | 10.0 | 40.0 | 0.01 | 0.2 | 0.2 | 10 | Foundation | 26.0 | 15.0 | 35.0 | 0.05 | 0.3 | 30 | 80 | Reservoir basin | 20.0 | 10.0 | 30.0 | 0.05 | 0.3 | 30 | 80 |
|
|