Research Article

Simulation Analysis and Scheme Optimization of Energy Consumption in Public Buildings

Table 5

Sensitivity of the external wall heat transfer coefficient to the total building energy consumption.

Scheme numberComprehensive heat transfer coefficient of the exterior wall (W/(m2·K))Total building energy consumption (MWh)Energy saving of total energy consumption (MWh)Energy-saving ratio (%)Sensitivity coefficient

WA10.803582.33−22.72−0.6380.0106
WA20.703574.51−14.89−0.4180.0105
WA30.603566.66−7.05−0.1980.0099
Base0.503559.6200
WA50.403551.498.130.2280.0114
WA50.303542.8916.730.4700.0118
WA60.203533.9725.650.7210.0120

Note. The base represents the benchmark scheme. Sensitivity analysis scheme for energy saving of the external wall comprehensive heat transfer coefficient expressed by WA1-6.