Simulation Analysis and Scheme Optimization of Energy Consumption in Public Buildings
Table 6
Design parameters of the building envelope energy-saving potential sequencing and recommended values.
| Design parameters of building envelope | Sensitivity coefficient | Sorting | Recommended values | Maximum | Minimum | Average |
| The comprehensive heat transfer coefficient of the exterior wall | 0.0120 | 0.0099 | 0.0111 | 5 | ≤0.5 W/(m2·K) | The comprehensive heat transfer coefficient of the roof | 0.0013 | 0.0009 | 0.0011 | 6 | As small as possible, if the criterion is met | The comprehensive heat transfer coefficient of the external windows | 0.0385 | 0.0318 | 0.0352 | 3 | As small as possible, if the criterion is met | The solar heat coefficient of the outer window | 0.0207 | 0.0118 | 0.0166 | 4 | 0.3795 W/(m2·K)∼0.44 W/(m2·K) | The ratio of the window to the wall | 0.0481 | 0.0354 | 0.0416 | 2 | As small as possible, if the functionality is met | The airtightness of the outer window | 0.0496 | 0.0457 | 0.0474 | 1 | The higher the level is, the more feasible the technology and economy are. The recommendation is above level 4 |
|
|