Advances in Civil Engineering / 2019 / Article / Tab 1

Research Article

Application of Analytical Solution to Steady-State Temperature Field by Double-Row-Pipe Freezing and Verification with Field Measurement: A Case Study of Connected Aisle

Table 1

Thickness of the frozen wall in each section calculated by analytical solutions.

SectionWest bell mouthEDCBAEast bell mouth

Single thickness (ξ/m)0.90.91.010.970.820.850.92
Row spacing (L/m)1.221.221.221.221.221.221.22
Total thickness (d/m)3.023.023.243.162.862.923.06

We are committed to sharing findings related to COVID-19 as quickly and safely as possible. Any author submitting a COVID-19 paper should notify us at help@hindawi.com to ensure their research is fast-tracked and made available on a preprint server as soon as possible. We will be providing unlimited waivers of publication charges for accepted articles related to COVID-19. Sign up here as a reviewer to help fast-track new submissions.