Research Article

A Framework to Assess the Seismic Resilience of Urban Hospitals

Table 2

Fragilities of basic events in the fault tree and repair time.

No.EventEDP(Median, dispersion)Repair time (days)

1Ventilator 1PFA(1, 0.5)(1, 0.5)
2RefrigeratorPFA(1, 0.5)(1, 0.5)
3Blood analyserPFA(0.5, 0.5)(1, 0.5)
4Urine analyserPFA(0.5, 0.5)(1, 0.5)
5CTPFA(1, 0.5)(0.2, 0.5)
6CT wallIDR(0.005, 0.4)
7DRPFA(1, 0.5)(0.2, 0.5)
8DR wallIDR(0.004, 0.4)
9Portable DRPFA(1, 0.5)(1, 0.5)
10Shadow-less lamp 1PFA(1, 0.5)(1, 0.5)
11Partition in OR1IDR(0.005, 0.4)
12Shadow-less lamp 1PFA(1, 0.5)(1, 0.5)
13Partition in OR2IDR(0.005, 0.4)
14Anesthesia machinePFA(1, 0.5)(1, 0.5)
15Ventilator 2PFA(1, 0.5)(1, 0.5)
16C-arm X-ray machinePFA(1, 0.5)(1, 0.5)
17Disinfection machinePFA(1, 0.5)(1, 0.5)
18Partition 3IDR(0.005, 0.4)
19Elevator 1PFA(0.39, 0.45)
20Elevator 2PFA(0.39, 0.45)
21Oxygen generatorPFA(1, 0.5)(1, 0.5)
22Oxygen pipePFA(1.5, 0.4)
23Distribution roomPFA(0.73, 0.45)(0.6, 0.4)