Research Article
Prediction of Punching Capacity of Slab-Column Connections without Transverse Reinforcement Based on a Backpropagation Neural Network
Table 5
Punching test parameters for the slab-column connections.
| Specimen number | (MPa) | (%) | (MPa) | (mm) | | | (kN) |
| S5-1 | 23.7 | 1.51004 | 459 | 150 | 5 | 1.66667 | 517 | S5-2 | 24.9 | 1.53971 | 459 | 150 | 5 | 1.66667 | 612 | S7-1 | 23.1 | 1.5762 | 459 | 150 | 7 | 1.66667 | 535 | S7-2 | 21.4 | 1.47108 | 459 | 150 | 7 | 1.66667 | 556 | C7-30-3 | 27 | 1.53373 | 453.6 | 150 | 7 | 1.66667 | 690 | C7-50-3 | 36.1 | 1.6086 | 453.6 | 150 | 7 | 1.66667 | 805 | C7-70-1 | 48.6 | 1.38443 | 453.6 | 150 | 7 | 1.66667 | 610 | C7-70-2 | 50.1 | 1.54283 | 453.6 | 150 | 7 | 1.66667 | 785 | C7-70-3 | 50.9 | 1.52514 | 453.6 | 150 | 7 | 1.66667 | 860 |
|
|