Research Article

Prediction of Punching Capacity of Slab-Column Connections without Transverse Reinforcement Based on a Backpropagation Neural Network

Table 5

Punching test parameters for the slab-column connections.

Specimen number (MPa) (%) (MPa) (mm) (kN)

S5-123.71.5100445915051.66667517
S5-224.91.5397145915051.66667612
S7-123.11.576245915071.66667535
S7-221.41.4710845915071.66667556
C7-30-3271.53373453.615071.66667690
C7-50-336.11.6086453.615071.66667805
C7-70-148.61.38443453.615071.66667610
C7-70-250.11.54283453.615071.66667785
C7-70-350.91.52514453.615071.66667860