Research Article
Small-Scale Void-Size Determination in Reinforced Concrete Using GPR
Figure 14
Experiment and processing result: (a) experimental void defects; (b) void defect in lower layer; (c) rebar in upper layer; (d) test result when void length = 6 cm; (e) filtered result of (d); (f) comparison between regression curve and experimental data.