Research Article

Global Seismic Fragility Functions for Low-Rise RC Frames with Construction Deficiencies

Figure 17

Fragility functions fitting based on Porter [36]. Median and standard deviation: 0.14 and 0.53 for slight damage, 0.29 and 0.53 for moderate damage, 0.62 and 0.53 for extensive damage, and 1.03 and 0.53 for incipient collapse.